Skip to Header
Skip to Main Content
Skip to Footer
home
Hello Guest,
Login?
0
Shopping Cart
0
Items -
$0
0
Items
Toggle navigation
Serving Military and Civilians
Home
Vet's Pledge
High Velocity Sizing Request
Conventional System Sizing Request
My Account
Contact Us
A2L
SEER2
Home
ICM Controls
Line Voltage Monitoring
ICM Controls ICM493-60A Single Phase Monitor with surge supression, UL Listed, 60A contactor
Zoom in on Image(s)
Email a friend
ICM Controls ICM493-60A Single Phase Monitor with surge supression, UL Listed, 60A contactor
Your Price:
$278.25
Part Number:
ICM493-60A
Put me on the Waiting List
Quantity
+
-
Add to Cart
Submit
product tabs
Description
ICM Controls ICM493-60A Single Phase Monitor with surge supression, UL Listed, 60A contactor
Line Voltage Monitor with Surge
The ICM493-60A is an advanced, single-phase line voltage monitor with a bank of surge arresters for added protection against brownouts, lightning strikes, power outages & recoveries, startup of larger equipment, power grid faults, short circuits and more. Includes a built-in 60A contactor to support larger systems. Housed in a NEMA Rated 3R enclosure for outdoor installations. UL Listed. Installs easily between the service disconnect and the condensing unit. Ideal for Mini-Splits or other valuable, single-phase equipment.
DETAILS:
Line Voltage Monitor with Surge
Protects against over and under voltage, rapid short cycling caused by transients, and high-power surges
Programmable set points to determine cutoff
Fault history feature records and retains the most recent occurred faults in non-volatile memory
Ideal for mini-splits, inverter compressors, and other condensing units
Bank of five L-L Surge Arresters
Built-in 60A Contactor
Easy to view, backlit digital display
Waterproof, NEMA–Rated 3R enclosure for outdoor use
Easy installation and setup
Limited lifetime product, up to a 3-year $10,000 connected equipment warranty
SPECIFICATIONS:
User Adjustable Settings
Voltage Setpoint:
200-240 VAC
Anti-Short Cycle Delay:
0.5-10 Minutes
Number of Surge Arresters Required for Operation:
0-5
Number of Retries:
1-5, Auto
Inputs
Line Voltage:
195-264 VAC
Frequency:
50-60 Hz
Accuracy:
+/- 2%, User Calibration
Output
Type:
Contactor; 2-Pole
Contactor Ratings: 60
A FLA, 360A LRA
Mechanical
NEMA Rated 3R Outdoor Enclosure
Dimensions:
8.25”L x 10.25”W x 6.37”H
WEIGHT/DIMENSIONS:
Weight: 11.4 lbs.
Height: 6.37?
Width: 10.25?
Length: 8.25?
category breadcrumbs
Browse Similar Items
ICM Controls
>
Surge Protection
×
Menu Links
Categories